As part of Fire Door Safety Week, Alfie Hosker, the Technical Manager at Secured by Design discusses the enhanced security & fire performance of door sets.
The tragic fire at the Grenfell Tower in June 2017 has led to much examination of the escape protocols for high rise buildings and the materials and products utilised with the build process.
Post Grenfell, the government quite rightly called for further investigations and Secured by Design (SBD) took an active part as a member of the Grenfell Technical Group, which was set up in March 2018 to provide technical advice specifically on entrance doorsets to individual flats – which includes the door, associated frame and all component parts, such as the glazing and door hardware.
The Group, which included other not-for-profit organisations including the Fire Industry Association (FIA) and the Door and Hardware Federation (DHF), met frequently throughout the rest of that year. Our comprehensive technical findings were duly reported to government via the Grenfell Independent Expert Panel.
Building on the collective expertise and experience within SBD, FIA and DHF the three organisations took the unprecedented step of collaborating on a document entitled ‘Guide For Selecting Flat Entrance Doorsets’ which was published in March 2019.
LATEST SECURITY JOURNAL UK NEWS UPDATES
Aimed at housing associations, landlords, building owners, developers and local authorities in England (but much of the advice is equally applicable to other countries of the UK, even though Building Regulations may differ slightly), the publication brings together the best collaborative advice available from the industry in one straightforward document to highlight the fundamental issues of fire safety and security for those selecting such doorsets.
Importantly, the publication makes the point that there is no conflict between fire and security with Building Regulations Approved Document B (fire) and Approved Document Q (security) carrying equal weight with neither taking precedence over the other.
The publication also covers
• Why only factory produced doorsets can meet both Approved Document B and Q
• What to look for in terms of performance for fire
• What to look for with third-party certification for fire
• What to look for regarding security
• Other performance affecting flat entrance doorsets
• Glazing considerations
• Assessments – what to be aware of
• Installation
• Maintenance
• Multi-occupancy buildings
• Government advice to Building Control
Last year, it came to the attention of Jon Cole, our Chief Operating Officer at Secured by Design, that smoke test evidence was not being included in certification schemes, as it was for fire resistance and security. We have subsequently revisited the possible life-threatening characteristics of fire rated doorsets, as asphyxiation caused by smoke inhalation is the most common cause of deaths in flats when a fire occurs.
Currently doorset thresholds can legitimately be tested to BS 476-31.1 or BS EN 1634-3 with the threshold taped up, and be assigned an ‘S’ designation (according to the guidance within Approved Document B) or an ‘Sa’ classification (when classified according to EN 13501-2), as the threshold gap is effectively discounted in both instances.
It is also possible to maintain designated smoke performances (i.e. S or Sa) when following the guidance given in BS 8214, which allows for a 3mm gap at the threshold in situations where fitting a threshold seal is not practicable.
It is the opinion of SBD that neither are acceptable in a ‘real world’ fire scenario. The former (taping up the threshold) proves nothing when the doorset is exposed to smoke in an apartment block and could therefore lead to smoke unnecessarily entering an area designed to be a safe haven.
The latter (the 3 mm gap allowance) has been independently proven to allow smoke leakage of up to 10.5m3/h/m – three times the allowance of 3m3/h/m in the current Building Regulations.
You can find out more about a series of tests commissioned by the Intumescent Fire Seals Association (IFSA) this here: https://www.ifsa.org.uk/wp-content/uploads/2021/04/IFSA-Fact-Sheet-02-v0321.pdf
As soon as we realised that smoke was at risk of not being treated in the same way as fire and security evidence, it was critical we sought to resolve this issue specifically for all Secured by Design Developments and by all doorset manufacturers recognised by us through our SBD Membership scheme.
n early 2021 we secured agreement from all of the UK certification bodies working in this area to incorporate smoke control into their fire and security schemes for flat/apartment entrance doorsets.
With the safety and security of residents in mind, we have confirmed our requirements for all fire, security and smoke rated doorsets carrying SBD approval to the UK test and certification organisations – i.e. all smoke control tests – should be conducted with the doorset threshold un-taped, and furthermore the allowance of a 3mm gap under the door will also be unacceptable.
Therefore, SBD will require all member companies with doorsets listed on their SBD schedule that are fire rated and that are required by UK Building Regulations (England, Scotland, Wales and Northern Ireland) to have smoke control properties for the intended installation – e.g. flat entrance doorsets to be certificated for the following attributes – Security, Fire and Smoke Control.
Thus, all SBD Fire, security and Smoke rated doorsets will require a thresh detail that enables the doorset to comply with the Building Regulation maximum requirement for smoke leakage of 3m3/h/m.
SBD has committed to both promoting our requirements and to support other organisations lobbying for change in this important area.
We are adamant that any doorset that carries SBD accreditation should be fit for purpose in all declared characteristics, but especially those that are life critical such as fire, security and smoke control.
We are committed to saving lives and making homes safer places in which to live, work and play.
The ‘Guide For Selecting Flat Entrance Doorsets’ is currently being updated to include these new SBD requirements. You can have confidence in using this publication as an authoritative source of information, which will guide you through the complexities of an extremely important area of Building Regulations. The publication can be downloaded for free here:
https://www.securedbydesign.com/images/downloads/DOORSET_BROCHURE_update_25.3.19.pdf
Click to Open Code Editor